The Safety Assessment of Wind-Photovoltaic Hybrid Power System for Afforestation in Desertification area

Dongseok Oh, Kwang-won Rhie, Jongyun Moon, Aulis Tuominen, The Safety Assessment of Wind-Photovoltaic Hybrid Power System for Afforestation in Desertification area. In: 2010.

Abstract:

In this paper, we introduce the wind-photovoltaic hybrid system (WPHS) installed in Mongolia and the safety assessment for the WPHS, which was implemented to prevent the failure mode. Failure mode and Effect Analysis was used as a safety assessment method in this study. Two groups of photovoltaic systems were installed. One of the generators, which produce 70kW of power, operates as the power plant for cultivation in this area and another one works with wind power generator. The 28 of important assemblies of WPHS were evaluated by FMEA and the results carried out 47 failure modes.

BibTeX entry:

@INPROCEEDINGS{pOhRhMoTu10a,
  title = {The Safety Assessment of Wind-Photovoltaic Hybrid Power System for Afforestation in Desertification area},
  author = {Oh, Dongseok and Rhie, Kwang-won and Moon, Jongyun and Tuominen, Aulis},
  year = {2010},
}

Belongs to TUCS Research Unit(s): TUCS Productization Laboratory